A great solution/s to interconnect Modbus RTU devices on Modbus RS485network.

Modbus RTU

Modbus RTU is a serial communication protocol. At the physical layer Modbus RTU can work on RS232 or RS485 based communication links. Modbus RTU works on a Client/Server architecture. There can be only one Client on a Modbus RTU network. The Client initiates the poll and the Servers respond to the Client’s request. If an RS232 based topology is used there can be only one Server connected to the Client. However if RS485 based topology is used it is possible to daisy chain up to 31 Servers and connect to the Client.

ProtoConvert can supply and support gateways that can have a Modbus RTU Client or a Server interfaces.

When a gateway is configured as a Modbus RTU Client it would keep reading data from the field devices using Modbus RTU protocol. It will also be possible to program the gateway to relay commands to the field device/s. Hence when used as a Modbus RTU Client the gateway reads data from Modbus RTU Servers like power meters, UPS’, PDUs, CRAC units and makes the data available on a variety of other protocols like BACnet, SNMP , LonWorks and many others.

When a gateway is configured as a Modbus RTU Server it can be connected to a Modbus RTU Client and be a source of data. It would respond to the polls from the Modbus Client and publish the data as per the internal configuration. Hence by using the gateway as a Modbus RTU Server it is possible to publish data from other protocol networks on the Modbus RTU network for the Client/PLC/SCADA to consume.

Modbus RS485

Modbus RTU is a serial communication protocol. At the physical layer Modbus RTU can work on RS232 or RS485 based communication links. Modbus RTU works on a Client/Server architecture. There can be only one Client on a Modbus RTU network. The Client initiates the poll and the Servers respond to the Client’s request. If an RS232 based topology is used there can be only one Server connected to the Client. However if RS485 based topology is used it is possible to daisy chain up to 31 Servers and connect to the Client.

ProtoConvert can supply and support gateways that can have a Modbus RTU Client or a Server interfaces.

When a gateway is configured as a Modbus RTU Client it would keep reading data from the field devices using Modbus RTU protocol. It will also be possible to program the gateway to relay commands to the field device/s. Hence when used as a Modbus RTU Client the gateway reads data from Modbus RTU Servers like power meters, UPS’, PDUs, CRAC units and makes the data available on a variety of other protocols like BACnet, SNMP , LonWorks and many others.

When a gateway is configured as a Modbus RTU Server it can be connected to a Modbus RTU Client and be a source of data. It would respond to the polls from the Modbus Client and publish the data as per the internal configuration. Hence by using the gateway as a Modbus RTU Server it is possible to publish data from other protocol networks on the Modbus RTU network for the Client/PLC/SCADA to consume.

Modbus RTU and Modbus RS485 datasheets are available for your review on this link for detailed information on the capabilities of these drivers.

The table below lists the various hardware options available with this protocol driver combination, please make a selection based on the point capacity, number of ports, and type of communication interfaces you require.

Name of Hardware with Tail CodePoint CapacityRS 485 portsRS 232 portsEthernet PortM-BusLonWorksKNXWiFi4G/LTEProduct Datasheet
FS-QS-2010-F25020100000Attachment
FS-QS-2110-F100020100000Attachment
FS-QS-2210-F50020100000Attachment
FS-QS-2310-F300020100000Attachment
FS-QS-2410-F500020100000Attachment
FS-QS-3010-F25020200000Attachment
FS-QS-3110-F50020200000Attachment
FS-QS-3210-F100020200000Attachment
FS-QS-3310-F300020200000Attachment
FS-QS-3410-F500020200000Attachment
FS-QS-3510-F1000020200000Attachment
PG-K30A-1K100020100000
PG-K30A-2K200020100000
PG-K30A-3K300020100000
PG-K30A-4K400020100000
PG-K30A-5K500020100000
PG7022-1K100021100000Attachment
PG7022-2K200021100000Attachment
PG7022-3K300021100000Attachment
PG7022-4K400021100000Attachment
PG7022-5K500021100000
PG7023-1K100031100000Attachment
PG7023-2K200031100000Attachment
PG7023-3K300031100000Attachment
PG7023-4K400031100000Attachment
PG7023-5K500031100000Attachment
PG7024-1K100041100000Attachment
PG7024-2K200041100000Attachment
PG7024-3K300041100000Attachment
PG7024-4K400041100000Attachment
PG7024-5K500041100000Attachment