The EZ Gateway Modbus to BACnet (FS-EZX-MOD-BAC) is a high-performance, user-friendly gateway for the building and industrial automation protocols that enables integrators to connect Modbus devices, such as power meters, flow meters, and other Modbus-based controllers, to BACnet networks in industrial buildings, campuses, and commercial buildings. The EZ Gateway can connect different types of Modbus to BACnet, including Modbus RTU, Modbus TCP/IP, BACnet/IP, and BACnet MS/TP, and it can handle up to 1000 data points.

The EZ Gateway quickly and simply meets the Modbus to BACnet integration requirements of a system integrator. With the EZ Gateway, the integrator or contractor can connect any Modbus device to a BACnet system using either BACnet protocol without having to be a protocol expert.

We continually include the newest Modbus developments on our FieldServer protocol gateways and extensively test them for interoperability thanks to our long-standing affiliation with the Modbus Organization and unwavering commitment to the Modbus standard. Our EZ Gateway Modbus to BACnet is compatible with virtually every Modbus device thanks to tried-and-true Modbus features like bit extracting, 32-bit float/integer support, and scaling. Quick commissioning of the devices is made possible by instant interoperability.

Unparalleled Performance

Two RS-485 ports on the EZ Gateway Modbus to BACnet enable connection for fewer devices per port, improving response time. Up to 64 Modbus RTU devices can be connected to the EZ Gateway using just two RS-485 ports, eliminating the need for repeaters on the RS-485 network. Our dual-port EZ Gateway can lower device connectivity costs or double the speed of connected devices compared to single-port gateways.

The EZ Gateway supports 100 Ethernet connections to Modbus TCP/IP devices. Additionally, in scenarios where the Modbus field devices also support concurrent polling, support for Modbus TCP/IP Concurrent Polling on our EZ Gateway enables quicker response times and more devices per segment.

1. MSA GRID SUPPORT

  • Register your EZ Gateway with the MSA Grid interface to access local apps, configure settings, and control devices remotely.

2. MODBUS FEATURES AND INTEROPERABILITY

  • From the start, you may connect to almost any Modbus device.
    • Modbus Data Manipulation: Bit extraction allows effective Modbus to BACnet device translation.
    • Modbus TCP/IP Concurrent Polling: The ability to respond more quickly and handle more devices per sector

3. MODBUS TO BACNET EZ PROFILES

  • Uploading predefined, certified Modbus-BACnet EZ Profiles can reduce commissioning time.

4. DEVICEPROXY™

  • Reduce management and operational costs by having granular visibility and control over each Modbus device from a BACnet management station.

5. DUAL RS-485 PORTS

  • Reduce response time by using fewer devices per port or supporting more devices per gateway. 

6. REMOTE ACCESS AND SUPPORT

  • Each FieldServer gateway supports remote access. Utilize the FieldServer gateway using the Remote Access feature after registering with the MSA Grid to keep an eye on, manage, and troubleshoot deployed equipment.
Get in Touch